Double LED Display Single Phase Adjustable Voltage Current Protector Voltage Protective Device AC230V 63A
Matters needing attention
1. The equipment must be installed by qualified professionals.
2. Before operating the device, disconnect all power supplies and do not touch any terminal when the power supply is connected.
3. Verify that terminals are properly connected.
4. No matter whether the equipment is in normal operation, do not disassemble or repair otherwise, producers and sellersNo responsibility is accepted.
5. Do not use the equipment in places that may be corroded by gas, strong sunlight and rain.
6. Clean equipment with a dry cloth
7. Failure to comply with these instructions will result in serious injury or serious accident.
Product characteristics
Microcontroller-based Digital display of operating voltage and current values
Prevent the electrical set voltage is too high/too low current, three-phase asymmetry and phase sequence errro
Voltage measurement accuracy 2%
Key setting parameter
LED indicates overvoltage/undervoltage and overcurrent faults 6 modules, DIN rail mounting
Technical data
Rated Supply Voltage |
AC 220V |
Operation voltage range
|
AC80V~440V(Single phase)
|
Rated Frequency |
50/60Hz |
Overyoltage(>Vjsetting range
|
240V~300V
|
Asymmetric delay |
10s |
Voltage measurement accuracy |
2 % (On the whole spectrum) |
Rated insulation voltage |
400V |
Output contact |
3NO |
Electrical life |
100000 |
Operating voltage range |
100000 |
Mechanical life |
100000 |
Protection class |
IP20 |
Pollution degree |
3 |
Operating temperature |
-5 ºC - 40 ºC |
Humidity |
≤50% or 40 ºC (Condensation free) |
Storage temperature |
-25 ºC - 55 ºC |
• Product status statement
• If a voltage fault is detected during the relay's reset/start delay count, the output relay turns on and the fault indicating LED lights up
The operating voltage and current values will be displayed on the screen when the relay is operating nonnally. If a voltage or current fault is detected, the output relay turns on and the fault indication LED lights up
Voltage failure: If the input voltage is detected to trip back to Hys after a voltage failure; During counting the relay will automatically reset reset/start delay fault indicator light off working voltage and current value flashing screen
Current failure: When the relay fails due tocurrent trip, it will reset automatically. Reset/start delay durring counting, farure indicator LED off operating voltage and current value flashing on the screen.
Wiring diagram (wiring is for reference only, subject to the actual)